Specifications

PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE 337
AR001 Disarmed
pgm: K-000:00
Pressing the [7] key once will show the 'P' on the screen, move the cursor to the right using the [Î] key.
AR001 Disarmed
pgm: KP000:00
Complete the entry by pressing [0], [0], [1] then the PGM output number by pressing [0] and [3] for the green
LED.
To enter a PGM group complete the same procedures as above however use the PG for the prefix in the
module type, the screen will change to only have 3 digits allowing the PGM group to be entered. See below for
an example of PGM group 4 at the same location as above.
AR001 Disarmed
pgm: PG004
Zone Entry
Zone entry is done by selecting the module type and then the address and actual zone number on the device.
For example to program the second zone on the fourth zone expander you would enter ZX004:02 where the ZX
is entered using the ascii mode similar to the text entry and the 004 and 02 are entered using normal decimal
mode entry.
In the following example we will program zone 6 on the Zone Expander at address 003 to be the REX Zone for
the Virtual Door.
FN001 REX
zone --000:00
In the above screen the default value for a zone is shown this is --000:00. To default the zone entry press the
[DISARM] key or to recall the currently programmed value press the [ARM] key. Pressing the [9] key 4 times will
put a 'Z' in the first location. Using the table in the Object Notation Section (see page 330) the zone expander is
referenced as a ZX. Press the [Î] arrow key to move to the next location.
FN001 REX
zone Z-000:00
Pressing the [9] key twice will show the 'X' on the screen, move the cursor to the right using the [Î] key.
FN001 REX
zone ZX000:00
Complete the entry by pressing [0], [0], [3] then the PGM output number by pressing [0] and [6] for zone 6.