Specifications
292 PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE
Analog Input/Output Expander
The Analog Input and Output Expanders will not report any zones as no physical connection is provided on the
Analog Input and Output expanders. Trouble zones will be reported.
Contact ID Large Trouble Zones
The following tables show the reporting codes for the trouble zones when the Contact ID Large Table is used
(Table 001).
Control Panel Trouble Zones
The control panel will report all trouble zones from 1 to 64 using any of the available table configurations.
Zone Number Contact ID Code Reporting Point Number
CP001:01 145 (Module Tamper) 501
CP001:02 301 (AC Loss) 502
CP001:03 302 (Low System Battery) 503
CP001:04 626 (RTC Inaccurate) 504
CP001:05 602 (Periodic Test Report) 505
CP001:06 354 (Fail To Communicate) 506
CP001:07 351 (Phone Line TLM Fail) 507
CP001:08 312 (Auxiliary Fuse) 508
CP001:09 145 (Bell/Siren 1 Tamper) 509
CP001:10 145 (Bell/Siren 2 Tamper) 510
CP001:11 321 (Bell/Siren 1 Over Current) 511
CP001:12 322 (Bell/Siren 2 Over Current) 512
CP001:13 143 (Module Lost) 513
CP001:14 143 (Module Security) 514
CP001:15 330 (Expansion Card Problem) 515
CP001:16 330 (COM Port 1 Problem) 516
CP001:17 330 (COM Port 2 Problem) 517
CP001:18 330 (COM Port 3 Problem) 518
CP001:19 330 (COM Port 4 Problem) 519
CP001:20 330 (Ethernet Link Failure) 520
CP001:21 331 (DVAC Failure To Poll) 521
CP001:22 331 (ModBUS Failure To Poll) 522
CP001:23 416 (Remote Interface Login) 523
CP001:24 466 (Installer Login UN00002) 524
CP001:25 415 (Service 1 Stopped) 525
CP001:26 415 (Service 2 Stopped) 526
CP001:27 415 (Service 3 Stopped) 527