Specifications
PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE 289
Zone Number Contact ID Code Reporting Point Number
AE001:05 140 (General Alarm) 969
AE001:06 140 (General Alarm) 970
AE001:07 140 (General Alarm) 971
AE001:08 143 (Module Offline) 972
AE002:01 145 (Module Tamper) 973
| | | | | | | |
AE002:08 143 (Module Offline) 980
AE003:01 145 (Module Tamper) 999
| | | | | | | |
AE250:16 143 (Module Offline) 999
In the above table a reporting code of 999 indicates that the trouble zone is outside the maximum trouble zones
that can be reported for the module type.
Contact ID Large Zones
The following tables show the reporting codes for the zones when the Contact ID Large Table is used (Table
001). The large table is ideally suited to predominantly burglary based installations that are comprised of a large
number of zone expansion modules.
Control Panel Zones
The control panel will report all zones from 1 to 16 using any of the available table configurations.
Zone Number Contact ID Code Reporting Point Number
CP001:01 130 (Burglary) 001
CP001:02 130 (Burglary) 002
CP001:03 130 (Burglary) 003
CP001:04 130 (Burglary) 004
CP001:05 130 (Burglary) 005
CP001:06 130 (Burglary) 006
CP001:07 130 (Burglary) 007
CP001:08 130 (Burglary) 008
CP001:09 130 (Burglary) 009
CP001:10 130 (Burglary) 010
CP001:11 130 (Burglary) 011
CP001:12 130 (Burglary) 012
CP001:13 130 (Burglary) 013
CP001:14 130 (Burglary) 014
CP001:15 130 (Burglary) 015
CP001:16 130 (Burglary) 016