Specifications
PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE 287
Zone Number Contact ID Code Reporting Point Number
ZX001:10 140 (General Alarm) 622
ZX001:11 140 (General Alarm) 623
ZX001:12 140 (General Alarm) 624
ZX001:13 140 (General Alarm) 625
ZX001:14 140 (General Alarm) 626
ZX001:15 140 (General Alarm) 627
ZX001:16 143 (Module Offline) 628
ZX002:01 145 (Module Tamper) 629
| | | | | | | |
ZX004:16 143 (Module Offline) 676
ZX005:01 145 (Module Tamper) 999
| | | | | | | |
ZX250:16 143 (Module Offline) 999
In the above table a reporting code of 999 indicates that the trouble zone is outside the maximum trouble zones
that can be reported for the module type.
2 Reader Expander
The 2 reader expander will report trouble zones from 1 to 16 on the first 16 modules, all modules above address
RD016 will be reported using the default code of 999.
Zone Number Contact ID Code Reporting Point Number
RD001:01 145 (Module Tamper) 677
RD001:02 301 (AC Loss) 678
RD001:03 302 (Low System Battery) 679
RD001:04 312 (Auxiliary Fuse) 680
RD001:05 312 (Lock Trouble) 681
RD001:06 423 (Door 1 Forced) 682
RD001:07 423 (Door 2 Forced) 683
RD001:08 426 (Door 1 Left Open) 684
RD001:09 426 (Door 2 Left Open) 685
RD001:10 312 (Reader 1 Power Supply) 686
RD001:11 312 (Reader 2 Power Supply) 687
RD001:12 145 (Reader 1 Tamper) 688
RD001:13 145 (Reader 2 Tamper) 689
RD001:14 461 (Door 1 Access Attempts) 690
RD001:15 461 (Door 2 Access Attempts) 691
RD001:16 143 (Module Offline) 692
RD002:01 145 (Module Tamper) 693