Specifications
PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE 283
Keypad Zones
The keypad will report zones from 1 to 4 on the first 6 modules, all modules above address KP006 will be
reported using the default code of 999.
Zone Number Contact ID Code Reporting Point Number
KP001:01 130 (Burglary) 017
KP001:02 130 (Burglary) 018
KP001:03 130 (Burglary) 019
KP001:04 130 (Burglary) 020
KP002:01 130 (Burglary) 021
KP002:02 130 (Burglary) 022
| | | | | | | |
KP006:04 130 (Burglary) 040
KP007:01 130 (Burglary) 999
| | | | | | | |
KP250:04 130 (Burglary) 999
In the above table a reporting code of 999 indicates that the zone is outside the maximum zones that can be
reported for the module type.
16 Zone Expander
The 16 zone expander will report zones from 1 to 16 on the first 4 modules, all modules above address ZX004
will be reported using the default code of 999.
Zone Number Contact ID Code Reporting Point Number
ZX001:01 130 (Burglary) 041
ZX001:02 130 (Burglary) 042
ZX001:03 130 (Burglary) 043
ZX001:04 130 (Burglary) 044
ZX001:05 130 (Burglary) 045
ZX001:06 130 (Burglary) 046
ZX001:07 130 (Burglary) 047
ZX001:08 130 (Burglary) 048
ZX001:09 130 (Burglary) 049
ZX001:10 130 (Burglary) 050
ZX001:11 130 (Burglary) 051
ZX001:12 130 (Burglary) 052
ZX001:13 130 (Burglary) 053
ZX001:14 130 (Burglary) 054
ZX001:15 130 (Burglary) 055
ZX001:16 130 (Burglary) 056