Specifications
PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE 273
Schedule Name
If the selected schedule entry has a name associated (some schedule entries may not have a name associated
with them) the name programming screen will be shown.
SC001 Name
*Schedule 001
To scroll schedule entries by name use the [Ð] and [Ï] keys. To modify or enter a new name for the selected
schedule item use the keypad as explained in section Entering Text and Names (see page 333) and press
[ENTER].
By default the schedule name will be prefixed by an '*' this indicates that the name is an editable name in the
system.
Schedule Miscellaneous Options
Miscellaneous options set the way the schedule will operate with the qualification PGM.
SC001 Misc
[--------]
To modify options, use the keypad as explained in section Entering Data Options (see page 336).
Option 1 - Qualify Schedule if PGM is On.
y Enabled the schedule will only operate if the qualify PGM is on and will be invalidated when the PGM turns
on if it was valid.
y Disabled the option will perform no action on the schedule.
Option 2 - Qualify Schedule if PGM is Off
y Enabled the schedule will only operate if the qualify PGM is OFF and will be invalidated when the PGM turns
off if it was valid.
y Disabled the option will perform no action on the schedule.
Option 3, 4, 5, 6, 7 8 - Reserved
y Reserved do not modify
Qualify Schedule Using PGM
The schedule can be qualified using a PGM. This means even if the schedule is valid the schedule can be made
invalid if the PGM turns on or off. This can be used to change the way a reader functions when the area arms.
The qualify schedule PGM can be used to prevent access to a door if a specific output has been activated.
SC001 Qualify
pgm: --000:00
To modify the period one start time use the keypad as explained in the section Entering Time and Date Values
(see page 334) and press [ENTER].
Period One Start Time
The schedule has a total of four periods. Each period defines a time for start and a time for end as well as the
days of the week that the period is valid on. A period also has the holiday groups that define how the period
functions if a holiday is active. To use period one program a starting time for the first period.
SC001 Start
P1 Time: --:--
To modify the period one start time use the keypad as explained in the section Entering Time and Date Values
(see page 334) and press [ENTER].