Specifications

258 PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE
Option 7 - Log Operating System Assertion Events
y Enabled the system controller will log operating system assertion events that occur. An assertion event is
generating when the system controller gets a value, command or performs a function that results in a
condition that is not deemed normal.
y Disabled the system controller will not log operating system assertion events.
Option 8 - Remote Login Not Required
y Enabled the system controller will not validate the login and user name that is provided from the remote
Protege System Management Suite or other remote host systems that must log in to the system.
y Disabled the system controller will require that any external host accessing the system uses a valid login and
user id number to gain access.
Miscellaneous Options
Miscellaneous options include configuration settings that affect the offline functions and remote intelligent door
reader operations.
Misc Options
[--------]
To modify options, use the keypad as explained in section Entering Data Options (see page 336).
Option 1 – Auto Update Offline Users
y Enabled the system controller will automatically update offline configuration parameters to all RDI modules
at the time programmed in the Offline User Update Time.
y Disabled the system controller will take no action for offline users.
Option 2 – Use Alternate Resistors
y Enabled the system controller will use alternate EOL configured resistors (2K2 and 6K8).
y Disabled the system controller will use the normal 1K and 1K resistor configuration.
Option 3 – Invert Module Tamper
y Enabled the system controller will invert the module tamper input allowing a normally open (door closed)
tamper switch to be used.
y Disabled the system controller will use the standard normally closed (door closed) tamper switch.
Option 4 - Reserved
y Reserved do not modify
Option 5 - Reset Anti-Passback Status On schedule
The anti-passback status of all users can be reset on schedule. This flag will enable this global function. The
associated 'Anti-Passback reset schedule' must also be set correctly for this option to function.
Option 6 - Enable Timed User Anti-Passback Reset
A specific time for Entry and Exit anti-passback can be set under the Door options to block a user from passing
through a door too often. The time can be individually specified per Door but is globally enabled using this
option flag.