Specifications

256 PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE
Panel IP Address
The system controller has a built in TCP/IP Ethernet Device and it must be programmed with a valid TCP/IP
Address to allow the software to connect. By default the IP address is set to 192.168.1.2.
Programming a IP address requires knowledge of the network and subnet that the system controller will be
connected to. ALWAYS consult the network or system administrator before programming these values.
IP Address
192.168.001.002
To modify the panel IP address use the decimal entry from (000 to 255), use the keypad as explained in section
Entering Decimal Numbers (see page 333) and press [ENTER]. Setting an address of 255 will disable the
communication.
Panel IP Netmask
In conjunction with the IP Address a netmask must be configured to allow access to the appropriate node on
the subnet. By default this is set to a value of 255.255.255.0.
Programming a IP Netmask requires knowledge of the network and subnet that the system controller will be
connected to. ALWAYS consult the network or system administrator before programming these values.
IP Address
255.255.255.000
To modify the panel IP netmask use the decimal entry from (000 to 255), use the keypad as explained in section
Entering Decimal Numbers (see page 333) and press [ENTER]. Setting an address of 255 will disable the
communication.
Panel IP Gateway
In conjunction with the IP Address a gateway can be configured to allow access to a router for external
communications beyond the subnet to which the system controller is connected. By default this is set to a value
of 0.0.0.0 to prevent any external communication.
Programming a IP Gateway requires knowledge of the network and subnet that the system controller will be
connected to. ALWAYS consult the network or system administrator before programming these values.
IP Gateway
000.000.000.000
To modify the panel IP gateway use the decimal entry from (000 to 255), use the keypad as explained in section
Entering Decimal Numbers (see page 333) and press [ENTER]. Setting an address of 255 will disable the
communication.
Panel Upload ID
The panel upload ID is used as a security key in combination with the host verify ID for communication with the
Protege System Management Suite. The upload and host ID keys prevent the remote connection of a Protege
System Management Suite other than that which has the same 32 bit keys.
Panel upload
ID: 00000000
To modify the panel upload id, use the keypad as explained in section Entering Hexadecimal Numbers (see
page 335) and press [ENTER].