Specifications

244 PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE
UNLOCKED
y Not Pulse Off
The not pulse off action will unlock the floor group only when the input one has transitioned from an ON to
an OFF state. The output will not be modified further from this state and will not be modified if it is turned
ON by another function.
Input One Output
LOCKED
Input One PGM
Input one selects the input source to the elevator control process that is being configured. Input one must be
programmed with a valid input source, if an input source is selected that is not valid when the function is started
an error will be generated and the function suspended. An input source can be a PGM (Programmable Output).
FN001 Input one
pgm: --000:00
To modify the input PGM, use the settings as explained in section Entering PGM and PGM Groups (see page
336).
Elevator Group
The elevator group selects the elevators to control as a result of the action being performed by the
programmable function.
FN001 Elev Grp
None
Use the [1] and [3] keys to scroll the action types until you reach the elevator group that you want to control and
then press [ENTER] to proceed to the next programmable option for the door control function. For more
information about the list control data entry refer to the section List Control Data Entry (see page 335).
Floor Group
The floor group selects the floors that will be activated on all of the elevators in the elevator group as a result of
the action being performed by the programmable function.
FN001 Floor Grp
None
Use the [1] and [3] keys to scroll the floor groups until you reach the required group and then press [ENTER] to
proceed to the next programmable option for the elevator control function. For more information about the list
control data entry refer to the section List Control Data Entry (see page 335).
Token Unlock Time
The token unlock time is the period of time the floor group will be activated for as a result of the action by the
programmable function.
FN001 Token
time: 010 secs