Specifications
242 PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE
Control PGM
The Control PGM's state will be followed by the Control Zone.
FN001 Control
pgm: CP001:01
Halted
To modify the Control PGM or PGM Group, use the settings as explained in section Entering PGM and PGM
Groups (see page 336).
Miscellaneous Options
These options are for the function.
FN001 Misc
[1--------]
Halted
Option 1 – Log Zone Events
y Enable Zone events when the zone changes state.
y Disable any Zone Events.
Option 2 - 8 – Reserved
y Reserved do not modify
Elevator Control
To program the Elevator Control function ensure that the function you have selected is halted. Select the
function type selection screen as shown below for Elevator Control.
FN001 Func Type
Elevator Ctrl
Use the [1] and [3] keys to scroll the function types until you reach the door control selection and press [ENTER]
to select the function type displayed and proceed to the next programmable option for the elevator control
function. For more information about the list control data entry refer to the section List Control Data Entry (see
page 335).
Function Mode
The function mode determines how this function operates with the system controller. By default a function is set
to normal operation. Normal operation will mean the function is started if it was running when the system
restarts or is completely powered down (AC Failure and Battery Failure). The Run Once mode of operation will
allow the function to run once and then wait to be stopped and started by the user or operator.
FN001 Func Mode
Normal
Use the [1] and [3] keys to scroll the function mode until you reach the normal selection and press [ENTER] to
proceed to the next programmable option for the elevator control function. For more information about the list
control data entry refer to the section List Control Data Entry (see page 335).