Specifications
240 PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE
Virtual Door Unlock Time
The unlock time determines how long the lock that controls the virtual door will remain unlocked for when a user
access's the door.
FN001 Unlock
time: 005 secs
To modify the unlock time (000 to 255 Seconds), use the keypad as explained in section Entering Decimal
Numbers (see page 333) and press [ENTER]. Setting a 000 value will result in the door not unlocking when a
users access's the door.
Virtual Door Maximum Open Time
The maximum open time is programmed to allow the door to be left open for a certain period before it will
generate a door left open condition. When the left open condition is reached this will activate the alarm PGM
and open the left open zone.
DR001 Pre-Alarm
time: 030 secs
To modify the pre-alarm time (000 to 255 Seconds), use the keypad as explained in section Entering Decimal
Numbers (see page 333) and press [ENTER]. Setting a 000 value will result in the pre-alarm feature not
operating.
Virtual Door Lock PGM or PGM Group
You can assign a PGM or PGM group that controls the physical electric lock for the door.
FN001 Door Lock
pgm: --000:00
To modify the door lock PGM or PGM Group, use the settings as explained in section Entering PGM and PGM
Groups (see page 336).
Alarm PGM or PGM Group
You can assign a PGM or PGM group that will activate when the door goes into either a left open or forced
condition. Use this to warn the user to close the door. See miscellaneous options below for configuring how
the PGM is activated.
DR001 Pre Alarm
pgm: --000:00
To modify the pre alarm PGM or PGM Group, use the settings as explained in section Entering PGM and PGM
Groups (see page 336).
Virtual Door Miscellaneous Options
These options are for the virtual door.
Option 1 – Alarm on Door Left Open
y The Alarm PGM will be activated when the door is left open beyond the Max Open time.
y The Alarm PGM is not activated.
Option 2 – Pulse Left Open Alarm
y The Alarm PGM will be activated with a pulse time on and off.
y The Alarm PGM will be turned on normally.