Specifications
236 PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE
The door status follows the programmed input one state and will retest the input state every 30 second
interval and change the door state accordingly.
Input One Door
ON UNLOCKED
OFF LOCKED
Test Action - If the door state is changed externally or is part of another programmable function the
programmable function will only restore the output state after 30 seconds has elapsed. This time is only
used if the programmable function was NOT responsible for the change in state. If a door has a door unlock
time and the door mode is set to timed this will unlock the door every 30 seconds.
y Not Follow and Test
Performs the same function as above however the output is inverted (NOT). This logic action is a test action,
consult the follow and test action for an explanation of the Test Function.
Input One Output
ON LOCKED
OFF UNLOCKED
y Pulse On
The pulse on action will unlock the door only when the input one has transitioned from an off to an on state.
The door will not be modified further from this state and will not be modified if it is turned OFF by another
function.
Input One Output
UNLOCKED
y Not Pulse On
The not pulse on action will lock the door only when the input one has transitioned from an off to an on
state. The door will not be modified further from this state and will not be modified if it is turned ON by
another function.
Input One Output
LOCKED
y Pulse Off
The pulse on action will unlock the door only when the input one has transitioned from an ON to an OFF
state. The door will not be modified further from this state and will not be modified if it is turned OFF by
another function.
Input One Output
UNLOCKED
y Not Pulse Off
The not pulse off action will unlock the door only when the input one has transitioned from an ON to an OFF
state. The output will not be modified further from this state and will not be modified if it is turned ON by
another function.
Input One Output
LOCKED