Specifications

PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE 207
Controlling PGM Outputs
To access the PGM output viewing and control menu login using a valid installer code and then select [MENU,
4, 8, 2, 1, 3]. The screen displays "Select PGM to view" as shown in the following example.
Select PGM to
view: CP001:01
Type the appropriate module type, module address and PGM number or use the [Ð] and [Ï] keys to scroll the
available PGM's. When the desired PGM number appears on the screen, press [ENTER] to view and control the
selected PGM number.
When selecting a PGM the address is entered using the Module Type, Module Address and the number of the
PGM on the module, this is called Protege Object Notation.
Information on the Protege Object Notation and how it applies to programmable objects within the Protege
System refer to the Object Notation Section (see page 330).
PGM Output Status Display
When the PGM is selected the name of the PGM will be displayed on the top line and the state of the PGM will
be shown on the bottom line.
Bell 1 Siren
is OFF
Use the [Ð] and [Ï] keys to scroll the available PGM's. Pressing the [ARM] key will toggle the display between
the name and the PGM identification. Each PGM Output is assigned a unique identification that uses the
Protege Notation.
CP001:01 PGM
is OFF
In the view screen, press the [1] key to activate the PGM for the programmed value, press the [2] key to
deactivate a PGM that is activated and press the [3] key to activate the PGM latched. Press the [Í] to return to
the PGM selection display.
The display will show the PGM states listed below.
OFF
PGM is deactivated.
ON
PGM is activated.
ON (Timed)
PGM is activated for a time period.
By default the PGM name will be shown on the top line of the screen however if no name is programmed or the
name is blank it may be desirable to view the device and address of the module that the PGM is connected to.
To view the PGM output in the system it is connected on press the [ARM] key, the [ARM] key can be pressed
repeatedly to toggle between the two display options.
Viewing Door Status
To access the door status and control menu login using a valid installer code and then select [MENU, 4, 8, 2,
1, 4]. The screen displays "Select Door to view" as shown in the following example.
Select Door to
view: DR001
Type the appropriate door number or use the [Ð] and [Ï] keys to scroll the available doors. When the desired
door number appears on the screen, press [ENTER] to view and control the selected door number.