Zone Status Display
When the zone is selected the name of the zone will be displayed on the top line and the state of the zone will
be shown on the bottom line.
Warehouse PIR
is TAMPERED
Use the [Ð] and [Ï] keys to scroll the available zones while in the view screen or press the [Í] to return to the
zone selection. Pressing the [ARM] key will toggle the display between the name and the zone identification.
Each zone is assigned a unique identification that uses the Protege Notation.
CP001:01 Zone
is TAMPERED
The display will show the zone state and will depend on the resistor configuration option programmed for the
zone that is being viewed. The possible states that can be displayed are:
OPEN
Zone is opened.
CLOSED
Zone is closed.
SHORT
Zone is shorted out or a wiring fault has occurred.
TAMPERED
Zone wiring is cut or faulty.
By default the zone name will be shown on the top line of the screen however if no name is programmed or the
name is blank it may be desirable to view the device and address of the module that the zone is connected to.
To view the input in the system it is connected on press the [ARM] key, the [ARM] key can be pressed
repeatedly to toggle between the two display options.
Viewing Trouble Zones
To access the trouble zone view menu login using a valid installer code and then select [MENU, 4, 8, 2, 1, 2].
The screen displays "Trouble zone to view" as shown in the following example.
Trouble zone to
view: CP001:01
Type the appropriate module type, module address and trouble zone number or use the [Ð] and [Ï] keys to
scroll the available trouble zones. When the desired trouble zone number appears on the screen, press [ENTER]
to view the selected trouble zone number.
When selecting a trouble zone the trouble zone address is entered using the Module Type, Module Address and
the number of the zone, this is called Protege Object Notation.
Information on the Protege Object Notation and how it applies to programmable objects within the Protege
System refer to the Object Notation Section (see page 330).
Trouble Zone Status Display
When the trouble zone is selected the name of the trouble zone will be displayed on the top line and the state of
the trouble zone will be shown on the bottom line. The Trouble Zone names are not able to be modified and
assigned by default.
CP001 Tamper
is OPEN
Use the [Ð] and [Ï] keys to scroll the available trouble zones while in the view screen or press the [Í] to return
to the trouble zone selection. Pressing the [ARM] key will toggle the display between the name and the trouble
zone identification. Each zone is assigned a unique identification that uses the Protege Notation.
The display will show the trouble zone states as detailed below.
OPEN
Zone is opened.
CLOSED