Specifications

202 PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE
Network Online Module View
Viewing modules that are online is performed by using the online module view function in the advanced network
section. To enter the module online view function select [MENU, 4, 8, 1, 2] the follow display explains the
screen information.
y Select the offline network menu item. The display will show that the system is scanning all modules to see if
any have gone offline.
Checking online
modules....
y If the system finds that a module is offline the module type and serial number will be displayed and a prompt
asking the user to check for the next offline module.
KP001 S:9781711F
Next module ?
The screen shows that PRT-KLCD located at address 001 is registered in the system with serial number
9781711F is online and operating correctly. Press the [Ð] key to check the next module.
y When the scanning for online modules is completed or there are no more modules to scan the display will
show the message below.
Online list
Completed.
To scan again press the [Ð] or press the [MENU] key to return to the main menu.
Network Module Reload
Reloading modules on the network will program the module with the configuration settings that are programmed
in the controller. This should be performed when programming of the system is completed. To enter the module
update function select [MENU, 4, 8, 1, 3] the following display explains the screen information and actions that
are performed.
y Select the update option from the network menu. The display will prompt to ask if you are sure you want to
reload the modules. If you want to continue with the update press the [ENTER] key, to cancel press the
[MENU] key.
Reload modules
are you sure?
y Pressing the [ENTER] key the keypad will display the message below if the module update has proceeded.
Reload modules
started....
If the screen displays a message that the update process could not start this is because another network
function has taken priority. When this is completed try to perform the update again.
Each module will be programmed with the configuration information.
Network Init and Reboot
Init and reboot modules on the network will program the module with the configuration settings that are
programmed in the controller and then perform a reset of the module. This should be performed when
programming of the system is completed. To enter the module update function select [MENU, 4, 8, 1, 4] the
following display explains the screen information and actions that are performed.
y Select the update init item from the module menu. The display will prompt to ask if you are sure you want to
update and init the modules. If you want to continue with the update press the [ENTER] key, to cancel
press the [MENU] key.
Init and reboot
are you sure?
y Pressing the [ENTER] key the keypad will display the message below if the module update has proceeded.