Specifications
PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE 201
Advanced
The advanced menu contains special functions, tests and allows control of objects in the Protege system. The
control of every PGM, Door and Zone is possible to allow for immediate diagnostic and testing to be completed.
Network functions including, updating, reset, offline, online and network protect are performed in the advanced
section.
To go to the advanced menu select [MENU, 4, 8]. You can then select from the menu items presented or scroll
the menu using the [Ï] and [Ð] keys.
Network Offline Module View
Viewing modules that are offline is performed by using the offline module view function in the advanced network
section. To enter the offline view select [MENU, 4, 8, 1, 1] the follow display explains the screen information.
y Select the offline network menu item. The display will show that the system is scanning all modules to see if
any have gone offline.
Checking offline
modules....
y If the system finds that a module is offline the module type and serial number will be displayed and a prompt
asking the user to check for the next offline module.
RD061 S:AC92B39D
Next module ?
The screen shows that PRT-RDI2 located at address 061 is registered in the system with serial number
AC92B39D has gone offline or failed to contact the controller. Press the [Ð] key to check the next module.
i
If the module was removed from the system or changed to another address use the network update
function to update all of the modules.
y When the scanning for offline modules is completed or there are no more modules to scan the display will
show the message below.
Offline list
Completed.