Specifications

200 PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE
Dial Attempt Number Phone Number Dialed Result
2 Phone Number 1 Fail
2 Back Up Phone Number Fail
3 Phone Number 1 Fail
3 Back Up Phone Number Fail
4 Phone Number 1 Fail
4 Back Up Phone Number Fail
5 Phone Number 1 Success (Report OK)
Success After 2nd Dialing Attempt With Phone Number 2
In the following example, the Controller was able to communicate with the central station only after phone
number 2 was dialed for the second time. This resulted in the opening of the reporting failure trouble zone as a
result of the reporting failure. This is subsequently sealed on the next valid report.
Dial Attempt Number Phone Number Dialed Result
1 Phone Number 1 Fail
1 Back Up Phone Number Fail
2 Phone Number 1 Fail
2 Back Up Phone Number Fail
3 Phone Number 1 Fail
3 Back Up Phone Number Fail
4 Phone Number 1 Fail
4 Back Up Phone Number Fail
5 Phone Number 1 Fail
5 Back Up Phone Number Fail
6 Phone Number 1 Fail
6 Back Up Phone Number Fail
7 Phone Number 1 Fail
7 Back Up Phone Number Fail
8 Phone Number 1 Fail (Trouble Zone CP001:06 Opened,
Failure To Communicate)
8 Back Up Phone Number Fail (Trouble Zone CP001:06 Opened,
Failure To Communicate)
1 Phone Number 2 Fail
2 Phone Number 2 Fail (Trouble Zone CP001:06 Closed)