Specifications

188 PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE
Service Mode
The service mode determines how this service operates with the system controller. By default a service is set to
start with the operating system. Setting a service to "Start With The Operating System" (Start With O/S) allows
the service to operate automatically, if the system controller is reset or restarts. Manual control of the service
can be set by using the Manual option for the service mode.
SV001 Ser Mode
Start with O/S
Use the [1] and [3] keys to scroll the available operating modes and press [ENTER] to select the operating mode
displayed. For more information about the list control data entry refer to the section List Control Data Entry (see
page 335).
Reporting Protocol
The reporting protocol defines how the IP communication data will be sent to the monitoring station. Various
protocols are supported to allow the most comprehensive solution.
SV001 Format
Armor IP
Use the [1] and [3] keys to scroll the different protocols and press [ENTER] to select the protocol displayed. For
more information about the list control data entry refer to the section List Control Data Entry (see page 335).
Protocol Function
Armor IP Armor IP will communicate to the Armor IP server software running on a remotely
connected server. The Amour IP Server provides a standard Ademco 685 output and
allows routing and redirection of signals to other reception devices such as E-Mail, SMS
Messaging and Websites. The Armor IP software is designed to be used with a
Concentrator operating in the central station control room.
CID Over IP CID Over IP communicates a Contact ID message using the SIA DC09 specification
format to any receiver that supports the SIA DC09 specification. SIA DC09 Specification
is currently not released as a formal specification and is subject to change.
SIA Over IP SIA Over IP communicates a SIA Level 2 message using the SIA DC09 specification
format to any receiver that supports the SIA DC09 specification. SIA DC09 Specification
is currently not released as a formal specification and is subject to change.
AlarmNZ IP AlarmNZ IP is the IP Communication format used by Alarm New Zealand Limited. By
default the AlarmNZ IP service will use the Contact ID reporting format. Information is
sent using a login and password and then event information in a ASCII comma separated
data format.
Patriot LS30 Patriot LS30 Protocol is the IP Communication format used by Patriot Systems central
station automation application. By default the Patriot LS30 service will use a form of
Contact ID reporting. Information is sent using a proprietary format and to obtain details
the user should contact Patriot Systems directly.