Specifications

182 PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE
Intercom Type
The Intercom Type selects the intercom that will be connected to the Serial Communications Interface.
SV001 Intercom
Siedle
Use the [1] and [3] keys to scroll the different intercom types and press [ENTER] to select the intercom
displayed. For more information about the list control data entry refer to the section List Control Data Entry (see
page 335).
Validation Mode Function
Siedle Select when connecting the Siedle range of intercoms. Integrates to the Bus Control
module by using an ACC-485 unit and appropriate RS232 cable to the PRT-COMM
serial interface.
Sentex Infinity Select when connecting to the Sentex Infinity Multiple Point intercoms from
Chamberlain group. Connects to the serial RS232 output of the intercom, may need a
suitable RS485 converter for distances above 15 meters.
Sentex Type L Select when connecting to the Sentex Type L single channel intercoms from
Chamberlain group. Connects to the serial RS232 output of the intercom, may need a
suitable RS485 converter for distances above 15 meters.
Enterphone Select when connecting to the Enterphone intercom system. Connects to the serial
RS232 output of the intercom, may need a suitable RS485 converter for distances
above 15 meters. The Enterphone unit does not support multi units and therefore does
not need to have the intercom address set.
Validation Mode
The Validation Mode determines how the intercom service will grant access and then provide a credit to an
elevator car. User Number will validate the user id from the Intercom System with the exact user number in the
Protege System Controller, User PIN will validate the user with a PIN number of a user and the User Card will
validate the user based on the programmed card number of a user.
SV001 Validate
User Number
Use the [1] and [3] keys to scroll the different Validation Types and press [ENTER] to select the validation type
displayed. For more information about the list control data entry refer to the section List Control Data Entry (see
page 335).
Validation Mode Function
User Number The user number (index) in to the Protege System controller's user table will be used.
This is typically used with fixed user id's for intercom control of doors and floors.
User Number Offset The user number (index) in to the Protege System controller's user table will be used
and an offset can be programmed. This is typically used with fixed user id's for
intercom floors.
PIN Number The PIN number of the programmed user will be used to identify the user from the
Intercom System.
Card Number The Card Number of the programmed user will be used to identify the user from the
Intercom System. The family number should be set to 0 unless instructions for the
intercom type specify a family number.