Specifications
PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE 171
Report OK PGM
The report ok PGM is activated when the service completes the reporting and the messages have been
successfully acknowledge. The PGM is activated when the service returns a reporting complete result OK
message. The PGM is not deactivated and should be programmed with a time. Connect to an external audible
device to signal that the report was completed. Using this feature with the shorten exit delay for an area allows
an end user to verify the communication path on arming of the protected area.
SV001 Report Ok
pgm: --000:00
To modify the report ok PGM, use the settings as explained in section Entering PGM and PGM Groups (see
page 336).
AMX Home Automation Service
To program the AMX home automation service ensure that the service that has been selected is halted. Press
the [ENTER] key until the display shows the service type selection screen.
SV001 Ser Type
AMX
Use the [1] and [3] keys to scroll the service types until you reach the AMX home automation selection and
press [ENTER] to select the AMX home automation type displayed and proceed to the next programmable
option for the AMX home automation service. For more information about the list control data entry refer to the
section List Control Data Entry (see page 335).
DVAC (Surgard) Reporting Service
To program the DVAC (Surgard) reporting service ensure that the service that has been selected is halted. Press
the [ENTER] key until the display shows the service type selection screen. The DVAC (Surgard) service is a
hard-line polled communication path utilized in North America across the BELL TELECOM network. A DVAC
hardline modem or F1/F2 subset MUST be connected to the communications port using a DVAC modem cable.
SV001 Ser Type
DVAC (Surgard)
Use the [1] and [3] keys to scroll the service types until you reach the DVAC (Surgard) reporting selection and
press [ENTER] to select the DVAC surgard reporting type displayed and proceed to the next programmable
option for the DVAC surgard reporting service. For more information about the list control data entry refer to the
section List Control Data Entry (see page 335).
i
The DVAC F1/F2 subset requires a RX/TX and GND connection; this can be connected from the
terminal block on the communications interface or the DB9 connector. Refer to the communication
PRT-COMM installation manual.
Service Mode
The service mode determines how this service operates with the system controller. By default a service is set to
start with the operating system. Setting a service to "Start With The Operating System" (Start With O/S) allows
the service to operate automatically, if the system controller is reset or restarts the service will automatically
restart with the operating system. Manual control of the service can be set by using the Manual option for the
service mode.
SV001 Ser Mode
Start with O/S
Use the [1] and [3] keys to scroll the available operating modes and press [ENTER] to select the operating mode
displayed. For more information about the list control data entry refer to the section List Control Data Entry (see
page 335).