Specifications

PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE 163
Poll Time
The poll time configures the number of seconds between each poll event when the service is configured to send
poll events.
SV001 Poll
time: 090 secs
To modify the poll time (000 to 255), use the keypad as explained in section Entering Decimal Numbers (see
page 333) and press [ENTER].
Encryption
All events sent back to the Protege System Management Suite when the controller is not connected are
encrypted. This parameter defines the type of encryption that is used.
SV001 Encryption
Default
Use the [1] and [3] keys to scroll the available parity and press [ENTER] to select the encryption displayed. For
more information about the list control data entry refer to the section List Control Data Entry (see page 335).
Encryption Key
When AES 128, 192 or 256 bit Encryption is selected this defines the AES key that is used.
SV001 Crypt Key
To modify or enter a new key use the keypad as explained in section Entering Text and Names (see page 333)
and press [ENTER].
Serial Printer Service
To program the serial printer service ensure that the service that has been selected is halted. Press the [ENTER]
key until the display shows the service type selection screen. By default the serial printer service is programmed
at SV004 and is running using the programmed TCP/IP address and port 10001.
SV001 Ser Type
Serial Printer
Use the [1] and [3] keys to scroll the service types until you reach the serial printer selection and press [ENTER]
to select the serial printer service type displayed and proceed to the next programmable option for the serial
printer service. For more information about the list control data entry refer to the section List Control Data Entry
(see page 335).
Service Mode
The service mode determines how this service operates with the system controller. By default a service is set to
start with the operating system. Setting a service to "Start With The Operating System" (Start With O/S) allows
the service to operate automatically, if the system controller is reset or restarts the service will automatically
restart with the operating system. Manual control of the service can be set by using the Manual option for the
service mode.
SV001 Ser Mode
Start with O/S
Use the [1] and [3] keys to scroll the available operating modes and press [ENTER] to select the operating mode
displayed. For more information about the list control data entry refer to the section List Control Data Entry (see
page 335).