Specifications

158 PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE
Option 1 - Telephone Line Monitoring
y Enabled the service monitor the telephone line for a disconnection or out of tolerance loop value. The TLM
failure will open the phone line trouble zone, for a list of trouble zones refer to the Trouble Zone section (see
page 94).
Only telephone line 1 (T1 and R1) can be monitored for telephone line or loop failures.
y Disabled the service will not monitor the telephone line.
Option 2 - Answer Machine Override
y Enabled the service will use the answer/fax machine override function.
y Disabled the service will answer the line based on the programmed number of rings to answer.
Option 3 - Call Back Security On Connection Request
y Enabled the service will allow a remote communication connection to login and will then call the connecting
party back using the PC phone number programmed in the service.
y Disabled the service will not use call back security.
Option 4 - Call Back On Event Buffer (75%)
y Enabled the service will call the PC phone number programmed in the service when the total number of
events that have not been enabled reaches 75% of the total available events.
y Disabled the service will not call back.
Option 5 - Log Modem Service Events
y Enabled the service will provide step by step event information showing the call progression and detailed
logging information. This option can be turned on for diagnostic purposes but should not be enabled as
large volumes of events are stored.
y Disabled the dialer will not log events.
Option 6 - Reserved
y Reserved do not modify
Option 7 - Reserved
y Reserved do not modify
Option 8 - Answer ModBUS Remote Receiver Mode
y Enabled the service will answer the phone line and wait for a ModBUS remote communication connection.
Setting this option will disable the ability to log in to the panel using the Protege System Management Suite.
This option should only be enabled for the ModBUS remote receiver unit. For information on the ModBUS
remote communication operation refer to the PRT-CTRL ModBUS Remote and Slave Communication
Protocol Reference Manual.
y Disabled the dialer will answer using the normal configuration settings.
Answering Machine Override Delay Time
The answering machine override setting determines the delay between the first group of rings that are generated
to the time that the panel will immediately hook and take the line in answer mode. The number of rings must be
less than 10 seconds and then the call back must occur within 30 seconds (default) of the initial rings. The
answer machine override option must be enabled for the operation to work.
SV001 AMO Delay
time: 030 secs
To modify the answer machine override delay (000 to 255, a setting of 000 will result in the default of 030
seconds), use the keypad as explained in section Entering Decimal Numbers (see page 333) and press
[ENTER].