Specifications
PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE 157
Off Hook PGM
The off hook PGM is activated when the service takes the telephone line and is deactivated when the service
completes communication. This PGM setting can be used with remote exchange systems that require ground
start communication connections.
SV001 Off Hook
pgm: --000:00
To modify the off hook PGM, use the settings as explained in section Entering PGM and PGM Groups (see page
336).
Report OK PGM
The report ok PGM is activated when the service completes the reporting and the messages have been
successfully acknowledge. The PGM is activated when the service returns a reporting complete result OK
message. The PGM is not deactivated and should be programmed with a timer, this can be connected to an
external audible device to signal that the report was completed. Using this feature with the shorten exit delay for
an area allows an end user to verify the communication path on arming of the building
SV001 Report Ok
pgm: --000:00
To modify the report ok PGM, use the settings as explained in section Entering PGM and PGM Groups (see
page 336).
Monitor Phone Service
To program the monitor phone service ensure that the service that has been selected is halted. Press the
[ENTER] key until the display shows the service type selection screen.
SV001 Ser Type
Monitor Phone
Use the [1] and [3] keys to scroll the service types until you reach the monitor phone selection and press
[ENTER] to select the monitor phone service type displayed and proceed to the next programmable option for
the monitor phone service. For more information about the list control data entry refer to the section List Control
Data Entry (see page 335).
Service Mode
The service mode determines how this service operates with the system controller. By default a service is set to
start with the operating system. Setting a service to Start With The Operating System (Start With O/S) allows the
service to operate automatically, if the system controller is reset or restarts the service will automatically restart
with the operating system. To stop and start the service manually and to prevent the service from restarting
when a reset condition occurs select manual operation.
SV001 Ser Mode
Start with O/S
Use the [1] and [3] keys to scroll the available operating modes and press [ENTER] to select the operating mode
displayed. For more information about the list control data entry refer to the section List Control Data Entry (see
page 335).
Miscellaneous Options
The miscellaneous options allow you to program special functions and features for the monitor phone service.
SV001 Misc
[--------]
To modify options, use the keypad as explained in section Entering Data Options (see page 336).