Specifications
154 PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE
Events Options
The events options allow you to filter the type of events that this contact ID service will send to the monitoring
station.
SV001 Events
[123456--]
To modify options, use the keypad as explained in section Entering Data Options (see page 336).
Option 1 - Report Opens
y Enabled the service will report opens (Disarming) for the areas that are part of the area group assigned. An
area group of none will mean ALL areas will be sent using this service.
y Disabled the dialer will not report opens.
Option 2 - Report Closes
y Enabled the service will report closes (Arming) for the areas that are part of the area group assigned. An
area group of none will mean ALL areas will be sent using this service.
y Disabled the dialer will not report closes.
Option 3 - Report Alarms
y Enabled the service will report alarms for the zones that are part of the area group assigned. An area group
of none will mean ALL areas will be sent using this service.
y Disabled the dialer will not report alarms.
Option 4 - Report Tampers
y Enabled the service will report tampers for the zones that are part of the area group assigned. An area
group of none will mean ALL areas will be sent using this service.
y Disabled the dialer will not report tampers.
Option 5 - Report Restore
y Enabled the service will report restores for the zones that are part of the area group assigned. An area
group of none will mean ALL areas will be sent using this service.
y Disabled the dialer will not report restores.
Option 6 - Report Bypass
y Enabled the service will report bypass's for the zones that are part of the area group assigned. An area
group of none will mean ALL areas will be sent using this service.
y Disabled the dialer will not report bypass's.
Option 7 and 8 - Reserved
y Reserved do not modify
Data Options
The data options are currently reserved and should not be modified from their default settings.
SV001 Data
[--------]
To modify options, use the keypad as explained in section Entering Data Options (see page 336).
Option 1 – Service Used For Back Up Operation
y Enabled the service will NOT report messages and alarms unless it is started by another service that has
failed. It will then start reporting messages immediately from the point that the service that started it failed to
report and then return operation to the service that started. This cycle will continue until the service that
failed operates normally.