Specifications

PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE 141
Elevator
Each elevator is assigned a unique elevator address. Elevators are used for the control of access by users or to
monitor and control floors in a multi story high rise buildings.
Elevator to
modify: EL001
To access elevator programming, login using a valid code that has access to the elevator programming menu
and then select [MENU, 4, 5, 3]. The screen will then prompt you to "Select a Elevator to modify" requesting
that you enter a elevator number. Type the appropriate 3-digit elevator number or use the [Ð] and [Ï] keys to
scroll the available elevators. When the desired elevator number appears on the screen, press [ENTER] to
program the selected elevator. The maximum number of elevators that can be programmed is limited by your
system's memory and configured profile.
To browse the elevators by name press [ENTER] when prompted for a elevator number to modify and then use
the [Ð] and [Ï] keys to scroll the available elevators by their name.
Selecting an Elevator to Modify
Each elevator is assigned a unique door number from 001 to 250. Your system will be limited to specific number
of elevators that are defined in the selected profile. For information on profiles refer to the Advanced
Programming Section (see page 201).
Elevator to
modify: EL001
Type the appropriate 3-digit elevator number or use the [Ð] and [Ï] keys to scroll the available elevator
numbers. When the desired elevator number appears on the screen, press [ENTER] to program the selected
elevator number. The maximum number of elevators that can be programmed is limited by your system's
memory and configured profile.
Elevator Name
If the selected elevator has a name associated (some elevators do not have a name associated with them) the
name programming screen will be shown.
EL001 Name
*Elevator 001
To scroll elevators by name use the [Ð] and [Ï] keys. To modify or enter a new name for the selected elevator
use the keypad as explained in section Entering Text and Names (see page 333) and press [ENTER].
By default the elevator name will be prefixed by an '*' this indicates that the name is an editable name in the
system. Some elevators do not have names, this is limited by the system memory and the profile configured.
General Options
General options configure the elevator for various operational modes and functions.
EL001 General
[--------]
To modify options, use the keypad as explained in section Entering Data Options (see page 336).
Option 1 – Destination Reporting Mode Enabled
y Enabled the elevator will operate in DRM mode allowing only one button to be selected by the user when
the present their card.
i
When using the DRM mode the PRT-PX16 modules that are used for elevator control must have a
PRT-PX16-DRI board attached to allow the connection of button feedback inputs.
y Disabled the elevator will operate in normal mode with one badge activating the appropriate floor relays for
the user.