Specifications
PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE 131
Inside Area
The inside area defines which area is on the inside of this door. This is used to prevent a user from gaining
access to a door when the area is armed and they can not disarm it as well as automatically disarming the area
when the door is accessed. Using the door and area control integrates the two systems and is an ideal solution
to false alarm prevention.
DR001 Inside
None
Use the [1] and [3] keys to scroll the inside area selection and press [ENTER] to select the inside area displayed.
For more information about the list control data entry refer to the section List Control Data Entry (see page 335).
Outside Area
The outside area defines which area is on the outside of this door. This is used to prevent a user from gaining
access to a door when the area is armed and they can not disarm it as well as automatically disarming the area
when the door is accessed. Using an inside and an outside area usually requires that the door is programmed
with both an entry and exit reader.
DR001 Outside
None
Use the [1] and [3] keys to scroll the outside area selection and press [ENTER] to select the outside area
displayed. For more information about the list control data entry refer to the section List Control Data Entry (see
page 335).
Lock Schedule
The lock schedule determines when this door will unlock at a scheduled time. For example an employee entry
door may require to be unlocked at 7am and locked at 5pm you would assign a suitable schedule here. Using
the unlock on late control option prevents the door unlocking on schedule until the first user access the door.
DR001 Lock Sch
None
Use the [1] and [3] keys to scroll the unlock schedule selection and press [ENTER] to select the schedule
displayed. For more information about the list control data entry refer to the section List Control Data Entry (see
page 335).
Unlock Time
The unlock time determines how long the lock that controls the door will remain unlocked for when a user
access's the door.
DR001 Unlock
time: 005 secs
To modify the unlock time (000 to 255 Seconds), use the keypad as explained in section Entering Decimal
Numbers (see page 333) and press [ENTER]. Setting a 000 value will result in the door not unlocking when a
users access's the door.