Count PGM Pulse ON Time
The count PGM pulse on time is used to make the PGM output pulse on and off when activated. The value
entered here must be greater than 0 and is in increments of 100ms. For example setting 10 will pulse the unit on
for 1 second and then off for the programmed time set in the pulse off section.
AR001 Count
time: 000 on
To modify the pulse on time (000 to 255 100ms Increments), use the keypad as explained in section Entering
Decimal Numbers (see page 333) and press [ENTER]. Both the on and off pulse settings must have a value
greater than 000 for this feature to operate.
Count PGM Pulse OFF Time
The count PGM pulse off time is used to make the PGM output pulse on and off when activated. The value
entered here must be greater than 0 and is in increments of 100ms. For example setting 10 will pulse the unit off
for 1 second and then on for the programmed time set in the pulse on section.
AR001 Count
time: 000 off
To modify the pulse on time (000 to 255 100ms Increments), use the keypad as explained in section Entering
Decimal Numbers (see page 333) and press [ENTER]. Both the on and off pulse settings must have a value
greater than 000 for this feature to operate.
Defer PGM or PGM Group
You can assign a PGM or PGM group to activate whenever the area begins the defer warning cycle and is
about to arm. The defer warning time is programmed in the defer time setting. The defer PGM or PGM Group
will be deactivated when the area begins the arming cycle or when the defer time is canceled by a user.
AR001 Defer arm
pgm: --000:00
To modify the Defer PGM or PGM Group, use the settings as explained in section Entering PGM and PGM
Groups (see page 336).
Defer PGM Pulse ON Time
The defer PGM pulse on time is used to make the PGM output pulse on and off when activated. The value
entered here must be greater than 0 and is in increments of 100ms. For example setting 10 will pulse the unit on
for 1 second and then off for the programmed time set in the pulse off section.
AR001 Defer arm
time: 000 on
To modify the pulse on time (000 to 255 100ms Increments), use the keypad as explained in section Entering
Decimal Numbers (see page 333) and press [ENTER]. Both the on and off pulse settings must have a value
greater than 000 for this feature to operate.