Specifications

120 PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE
Bypass PGM Pulse OFF Time
The bypass PGM pulse off time is used to make the PGM output pulse on and off when activated. The value
entered here must be greater than 0 and is in increments of 100ms. For example setting 10 will pulse the unit off
for 1 second and then on for the programmed time set in the pulse on section.
AR001 Bypass
time: 000 off
To modify the pulse on time (000 to 255 100ms Increments), use the keypad as explained in section Entering
Decimal Numbers (see page 333) and press [ENTER]. Both the on and off pulse settings must have a value
greater than 000 for this feature to operate.
Tamper PGM or PGM Group
You can assign a PGM or PGM group to activate whenever the area has a tamper alarm. The tamper PGM or
PGM Group will be deactivated when the area completes the disarming cycle on the 24HR portion of the area.
AR001 Tamper
pgm: --000:00
To modify the Tamper PGM or PGM Group, use the settings as explained in section Entering PGM and PGM
Groups (see page 336).
Tamper PGM Pulse ON Time
The tamper PGM pulse on time is used to make the PGM output pulse on and off when activated. The value
entered here must be greater than 0 and is in increments of 100ms. For example setting 10 will pulse the unit on
for 1 second and then off for the programmed time set in the pulse off section.
AR001 Tamper
time: 000 on
To modify the pulse on time (000 to 255 100ms Increments), use the keypad as explained in section Entering
Decimal Numbers (see page 333) and press [ENTER]. Both the on and off pulse settings must have a value
greater than 000 for this feature to operate.
Tamper PGM Pulse OFF Time
The tamper PGM pulse off time is used to make the PGM output pulse on and off when activated. The value
entered here must be greater than 0 and is in increments of 100ms. For example setting 10 will pulse the unit off
for 1 second and then on for the programmed time set in the pulse on section.
AR001 Tamper
time: 000 off
To modify the pulse on time (000 to 255 100ms Increments), use the keypad as explained in section Entering
Decimal Numbers (see page 333) and press [ENTER].
Both the on and off pulse settings must have a value greater than 000 for this feature to operate.