Specifications
106 PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE
Zone Extra Options
Additional options for setting up the Zone Type.
ZT001 Extra
[--------]
To modify options, use the keypad as explained in section Entering Data Options (see page 336).
Option 1 - Always Log Zone Event
y Enabled, if the 'Log to Event Buffer' option in the Zone options is deselected, then over-ride this and log the
Event anyway.
y Disabled, log the event only as required by other settings
Option 2 - Retrigger PGM time
y Enabled, each time the Zone activates it will restart the associated PGMs time out counter.
y Disabled, the Zone will not retrigger the PGM time.
Options 3, 4, 5, 6, 7 and 8 - Reserved
y Reserved do not modify
Enabling/disabling or modifying the settings of reserved options is not recommended.
Zone Control PGM Options
Zone PGM options for the zone type, configure how the zone type will process the activation of the PGM
assigned to the zone (not the zone type).
ZT001 Zone Ctrl
[--------]
To modify options, use the keypad as explained in section Entering Data Options (see page 336).
Option 1 – Use Zone Type PGM Time
y Enabled the zone will activate the PGM timed (if a time is programmed) and use the PGM Time Set in the
Zone Type. If the zone type does not have a time programmed no time will be used.
y Disabled the zone will activate using the PGM timer if it is set to a value greater than 0.
Option 2 - Activate Control PGM On Alarm
y Enabled the zone type will activate the zone control PGM when the zone assigned generates an alarm.
y Disabled the zone type takes no action on the control PGM.
Option 3 - Activate Control PGM On Restore
y Enabled the zone type will activate the zone control PGM when the zone assigned restores from an alarm.
y Disabled the zone type takes no action on the zone control PGM.
Option 4 - Deactivate Control PGM On Alarm
y Enabled the zone type will de-activate the zone control PGM when the zone assigned generates an alarm.
y Disabled the zone type takes no action on the zone control PGM.
Option 5 - Deactivate Control PGM On Restore
y Enabled the zone type will de-activate when the zone control PGM assigned restores from an alarm.
y Disabled the zone type takes no action on the zone control PGM.