Specifications
PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE 105
Zone Type Automation Options
Automation options for the zone type configure options for various functions that relate to the control of
automation control settings. The options to control the 24Hr bell are also located in the Automation options.
ZT001 Auto Ctrl
[--------]
To modify options, use the keypad as explained in section Entering Data Options (see page 336).
Option 1 - Activate Automation on Alarm
y Enabled the zone type will activate the automation point when the zone assigned this zone type goes in to
alarm.
y Disabled the zone type takes no action on the automation point.
Option 2 - Activate Automation on Restore
y Enabled the zone type will activate the automation point when the zone assigned this zone type goes in to
alarm.
y Disabled the zone type takes no action on the automation point.
Option 3 - Deactivate Automation on Alarm
y Enabled the zone type will deactivate the automation point when the zone assigned this zone type goes in
to alarm.
y Disabled the zone type takes no action on the automation point.
Option 4 - Deactivate Automation on Restore
y Enabled the zone type will deactivate the automation point when the zone assigned the zone type restores.
y Disabled the zone type takes no action on the automation point.
Option 5 - Toggle Automation State on Alarm
y Enabled the zone type will toggle the current state of the automation number that has been assigned.
y Disabled the zone type takes no action on the automation point.
Option 6 - 24HR Audible If Area Armed
y Enabled the zone type will activate the bell PGM if a 24HR alarm is generated when the area is armed.
Please note that this option will be overridden by option 6 and will have no affect.
y Disabled the 24HR will be silent. This will have no affect if option 6 is enabled.
Option 7 - 24HR Always Audible
y Enabled the zone type will always activate the bell PGM for the area if a 24HR tamper alarm occurs. This
option will override option 5 when enabled.
y Disabled the 24HR will be silent.
Option 8 - Reserved
y Reserved do not modify