Specifications
102 PRT-CTRL-SE Protege System Controller Reference Manual | PRT-CTRL-SE
Zone Type Report Options
Reporting options for the zone type configure the operation of the zone type when reporting to a communication
service and includes options for various other zone type options.
ZT001 Report
[--------]
To modify options, use the keypad as explained in section Entering Data Options (see page 336).
Option 1 - Report Alarm
y Enabled the zone type will generate a reportable alarm message.
y Disabled the zone type does not generate a reportable alarm message.
Option 2 - Report Tamper
y Enabled the zone type will generate a reportable tamper message.
y Disabled the zone type does not generate a reportable tamper message.
Option 3 - Report Bypass
y Enabled the zone type will generate a reportable bypass message.
y Disabled the zone type does not generate a reportable bypass message.
Option 4 - Report Restore
y Enabled the zone type will generate a reportable restore message.
y Disabled the zone type does not generate a reportable restore message.
Option 5 - Stay Zone
y Enabled the zone type will generate an alarm if the area is armed in stay mode. The zone will stay armed.
For zones that will be active when an area is armed in stay mode it is recommended to disable the event log
for the zone.
y Disabled the zone type operates normally.
Option 6 - Force Zone
y Enabled the zone type will allow the zones it is assigned to be force armed.
y Disabled the zone type operates normally.
Option 7 - No Exit Test
y Enabled the zone type will not verify the status of a zone prior to the area starting to arm. Use this feature to
assign zones in exit locations to prevent the area from generating a zone open warning when being armed.
y Disabled the zone type operates normally.
Option 8 - Recycle Zone On Exit Delay
y Enabled the zone type will recheck the zones it is assigned when the area completes the exit delay cycle
and if a zone is open recycle the zone to force it in to generating an alarm.
Use this feature for a zone type used on a zone that may be breached during the exit delay such as a
window or door contact.
y Disabled the zone type operates normally.