Installation manual
DisplayOpons
The display opons are not relevant to and not used by the Protégé® EliteSuite® Eclipse LED
Keypad.
ArmingOpons
ReporngOpons
Opon Descripon
Fast Arming Enabled When enabled, the system can be FAST ARMED by pressing and
holding the Arm key.
Fast Stay Arming Enabled When enabled, the system can be FAST STAY armed by pressing
and holding the Stay key.
Fast Instant Arming Enabled When enabled, the system will allow the Stay key to be pressed
and held during the exit delay of a stay arming cycle to allow the
stay arming to be changed to an instant arm.
Fast Force Arming Enabled When enabled, the system can be FAST FORCE armed by pressing
and holding the Force key.
Opon Descripon
Report Arming/Disarming When enabled, the Protégé® EliteSuite® Eclipse LED Keypad will
send a message to the system controller when the system is armed
or disarmed. If this opon is disabled the current status of the
Protégé® EliteSuite® Eclipse LED Keypad will not be valid. It is
recommended this and the Report Alarm opons are always
enabled.
Report alarm Acvaon When enabled the Protégé® EliteSuite® Eclipse LED Keypad will
send a message when an alarm occurs on the EliteSuite® System.
This also enables the sending of the alarm silenced and alarm
med out messages.
Report Zone Bypassed When enabled, the system will report when the EliteSuite system is
armed with zones that have been bypassed.
Report Zone Fault When enabled, the system will report any zone fault trouble
condion to the system controller. This will not indicate the zone
that has the fault as this will be shown on the local keypad and in
the trouble view menu.
Report User Menu Access When enabled, the system will report when the master user has
accessed the main menu.
Report Local Installer Access When enabled, the system will report when the local installer code
is used to gain access to the local installaon opons.
Report Extended Informaon When enabled, the system will report extended informaon such
as the device tamper and re loop trouble condions. These
condions do not generate an alarm in the system locally but can
be used to generate an event at the local monitoring or remote
monitoring centre alerng the operator to a potenal problem.
39