Installation manual

Opon Descripon
Non-Duplex Zone EOL enabled If Duplex Zone Mode (Opon 2) is not enabled then Non-Duplex
Zone EOL enabled will set the zone input conguraon (EOL or
NO EOL). EOL requires the use of 2 x 1K resistors to provide, short,
alarm, closed and tamper monitoring. NO EOL provides alarm and
closed monitoring. If this opon is not enabled then no EOL
resistors are used.
Duplex Zone Mode Enabled When Duplex Zone Mode is enabled the zones will use a 1K and
2K4 resistor and provide monitoring for 2 zones per input. If this
opon is enabled then Non-Duplex Zone EOL (Opon 1) has no
funcon.
Beep On Trouble Condion When enabled, the beeper will emit 2 beeps every minute if a
trouble condion is present. To silence the trouble beep, view the
trouble condion.
Disarmed on Power up When enabled, the system will power up disarmed regardless of
the system status at the me power was lost.
When disabled, the system will power up in an exit delay condion
if the power to the EliteSuite® device was turned o during an exit
delay cycle or if the system was armed. If the system was in alarm
or was in the entry delay state then it will go into the alarm state
when power is restored.
Reader Network Enabled Not relevant to and not used by the Protégé® EliteSuite® Eclipse
LED Keypad.
PGM Follows Alarm Status When enabled, the PGM Output will be enabled with the alarm
siren me acvaon or re alarm acvaon.
Disabled, the PGM Output will not change state regardless of the
alarm status.
PGM Follows Area Status When enabled, the PGM Output will be enabled when the
EliteSuite® System is armed, and disabled when the system is
disarmed. When disabled, the PGM Output will not change state
regardless of the area status.
PGM Output Inverted When enabled, the PGM Output will follow the operaon
programmed by ‘PGM Follows Alarm Status’ and ‘PGM Follows
Area Status’, but the output will be opposite to the behavior
described in those funcons.
When disabled, the PGM Output will follow the programmed
output behavior of opons ‘PGM Follows Alarm Status’ and ‘PGM
Follows Area Status’.
38