Installation manual
36
Opon Descripon
Display Text This is a name by which the area can be referenced. It is only
relevant within the Protégé® Soware.
Zone1, Name This is a name by which the zone can be referenced. It is only
relevant within the Protégé® Soware.
Zone1, Zone Type The Zone Type needs to be specied for each zone and is dened
as follows:
Disabled Zone is disabled, does not funcon in the system.
Delay Zone will have an entry delay when a user enters.
Follow Zone will not cause an alarm if the entry delay
has started otherwise the zone will be an instant
zone. Use this to set the Zone Type for a moon
detector that is located in an entrance area.
Instant Zone will cause an alarm immediately.
24 hour Zone will always cause an alarm immediately.
Fire Zone Zone is a re zone and will generate an instant
alarm.
Fire delay Zone is a delayed re zone and will generate the
re delay beeping and require the user to follow
the delay re zone procedures to prevent a full
re alarm from being acvated.
Zone1, Bypass When enabled, the zone can be bypassed. A re zone can never be
bypassed regardless of the bypass seng.
When disabled, the zone cannot be bypassed.
Zone1, Stay When enabled, the zone is set as a stay zone. When the system is
armed in stay mode this zone will not generate an alarm.
When disabled, the zone is not a Stay zone.
Zone1, Force When enabled, the zone can be force armed when it is not ready
to be armed. A force armed zone will automacally be included in
the alarm processing when the zone restores from the not ready
condion.
When disabled, the zone is not able to be force armed.
Entry Time This is the me in seconds between the triggering of a Delay zone
and the generaon of the alarm. It can be set to any value from 0
to 255 seconds.
Exit Time This is the me in seconds between arming the system and an
open zone generang an alarm. It can be set to any value from 0 to
255 seconds.
Siren Time This is the me in minutes that the PGM will remain closed aer an
alarm has been generated. It can be set to any value from 0 to 250
minutes.