Installation manual

13.0 Zones (Menu 3)
The eight zones of the Protégé® EliteSuite® Eclipse LED Keypad can be individually congured as
one of seven zone types and can have specic opons assigned to them. The secons Selecng a
Zone, Zone Type and Zone Opons are intended to be followed one aer the other in order to set
up a zone.
13.1SelecngaZone
Step 1
To enter the Zone Number selecon menu enter the following key press sequence:
, 3,
Step 2
Select the zone which you wish to view or alter by pressing the number key corresponding the
desired zone. When the number key is pressed the number LED will stay lit to indicate the
selecon.
Step 3
Press the ENTER key ( ) to conrm your selecon.
13.2 Zone Type
Once you have selected a zone, (refertosecon13.1) you must select the Zone Type.
Step 1
Select the Zone Type by pressing the number key corresponding the desired Zone Type. When the
number key is pressed the number LED will stay lit to indicate the selecon.
Step 2
Press the ENTER key ( ) to conrm your selecon. Pressing the MENU key ( ) will abort the
operaon without saving any changes.
You must select a Zone Type from the following list:
Zone Types
1 Disabled Zone is disabled, does not funcon in the system.
2 Delay Zone will have an entry delay when a user enters.
3 Follow
Zone will not cause an alarm if the entry delay has started otherwise the zone will be an instant
zone. Use this to set the Zone Type for a moon detector that is located in an entrance area.
4 Instant Zone will cause alarm immediately.
5 24hr Zone will always cause an alarm immediately.
6 Fire Zone is a re zone and will generate and instant alarm.
7 Fire Delay
Zone is a delayed re zone and will generate the re delay beeping and require the user to follow
the delay re zone procedures to prevent a full re alarm from being acvated.
29