Installation manual

Opon 4 - Report Zone Fault
Enabled, the system will report any zone fault trouble condion to the system controller. This
will not indicate the zone that has the fault as this will be shown on the local keypad and in the
trouble view menu.
Disabled, no zone fault message will be sent.
Opon 5 - Report User Menu Access
Enabled, the system will report when the master user has accessed the main menu.
Disabled, no message will be sent when the master access’s the main menu.
Opon 6 - Report Local Installer Access
Enabled, the system will report when the local installer code is used to gain access to the local
installaon opons.
Disabled, no message will be sent when the installer access’s the installer menu.
Opon 7 - Report Extended Informaon
Enabled, the system will report extended informaon such as the device tamper and re loop
trouble condions. These condions do not generate an alarm in the system locally but can be
used to generate an event at the local monitoring or remote monitoring centre alerng the
operator to a potenal problem.
Disabled, no message will be sent when the extended funcons are triggered.
Opon 8 - Reserved
!
It is recommended not to enable/disable or modify the sengs of reserved
opons.