Installation manual

Opon 4 - Device Power Up Disarmed
Enabled, the system will power up disarmed regardless of the system status at the me power
was lost.
Disabled, the system will power up in an exit delay condion if the power to the Protégé®
EliteSuite® device was turned o during an exit delay cycle or if the system was armed. If the
system was in alarm or was in the entry delay state then it will go into the alarm state when
power is restored.
Opon 5 - Reserved
Opon 6 - PGM Output Follows Alarm Status
Enabled, the PGM Output will be enabled with the alarm siren me acvaon or re alarm
acvaon.
Disabled, the PGM Output will not change state regardless of the alarm status.
Opon 7 - PGM Output Follows Area Status
Enabled, the PGM Output will be enabled with the alarm siren me acvaon or re alarm
acvaon.
Disabled, the PGM Output will not change state regardless of the alarm status.
Opon 8 - PGM Output Inversion
Enabled, the PGM Output will follow the operaon programmed by Opons 6 and 7, but the
output will be opposite to the behaviour described in those funcons.
Disabled, the PGM Output will follow the programmed output behavior of Opons 6 and 7.
!
It is recommended not to enable/disable or modify the sengs of reserved
opons.