Installation manual
12.0 Opons (Menu 2)
12.1GeneralOpons(Menu2,1)
The General Opons set opons that relate to the general operaon of the Protégé® EliteSuite®
Eclipse LED Keypad.
Step 1
To enter the General Opons menu enter the following key press sequence:
, 2, 1
The currently assigned values will be displayed using the number LED’s.
Step 2
To toggle opons press the keys 1 to 8, and the corresponding number LED will be lit when that
opon is enabled.
Step 3
Pressing the ENTER key ( ) will save the opons. Pressing the MENU key ( ) will abort the
operaon without saving any changes.
The available opons are:
Opon 1 - Zone Type Opon 1
If Duplex Zone (Opon 2) is not enabled then Opon 1 will set the Zone Input Conguraon (EOL
or NO EOL). EOL requires the use of 2x 1k resistors to provide, Short, Alarm, Closed and Tamper
monitoring. NO EOL provides alarm and closed monitoring.
• Enabled, EOL resistors are used (2R Mode) (2 zones).
• Disabled, NO EOL resistors are used (2 zones).
Opon 2 - Duplex Zone Operaon
If Opon 2 is set Opon 1 does not have any funcon. When Opon 2 is set the zones will use a
1k and 2k4 resistor and provide monitoring for 2 zones.
• Enabled, Duplex Zone Mode (4 zones).
• Disabled, Opon 1 sets the zone conguraon.
Opon 3 - Beep On Trouble Condion
• Enabled, the beeper will emit 2 beeps every minute if a trouble condion is present, to silence
the trouble beep, view the trouble condion.
• Disabled, no trouble beep will be generated.
23