Installation manual
9.5FirmwareVersion(Menu4)
The Protégé® EliteSuite® Eclipse LED Keypad contains two microprocessors each with it’s own
rmware.
Step 1
To view the version of rmware that is installed in the main microprocessor enter the following key
press sequence:
, 4, 1,
The main microprocessor rmware version will be displayed as a sequence of four Number LED’s
lighng one aer the other. The rst two digits are the major version number and the second two
digits are the minor version number.
Step 2
To view the version of rmware that is installed in the keypad microprocessor enter the following
key press sequence:
, 4, 2,
The keypad microprocessor rmware version will be displayed as a sequence of four number LED’s
lighng one aer the other. The rst two digits are the major version number and the second two
digits are the minor version number.
9.6DeviceDefault(Menu5)
Step 1
To Default all the Device Opons enter the following key press sequence:
, 5
The ARMED LED will now ash more rapidly.
Step 2
Press the ENTER key ( ) to conrm or the MENU key ( ) to cancel.
9.7ExingDeviceConguraonMode
Step 1
Once Device Conguraon is complete, press the CLEAR key ( ) to restart the keypad.
!
If you do not press any key for 45 seconds while in Device Conguraon mode, the
keypad will automacally restart.
19