Installation manual
4.3 Zone Input Wiring
The Protégé® EliteSuite® Eclipse LED Keypad is capable of connecng to 8 zone inputs, each zone
input can then be programmed to perform the required funcon in the system.
The following diagrams show each of the zone wiring conguraon sengs that are possible.
The programmed zone conguraon for the Protégé® EliteSuite® Eclipse LED Keypad is made in the
opon sengs. RefertotheGeneralOponssecononpage23forprogrammingofthezone
conguraon.
!
When using a tamper input on a device the tamper contacts must be normally
closed and wired in series.
!
All resistors required to wire the zone conguraons are provided with the
Protégé® EliteSuite® Eclipse LED Keypad in the accessory bag.
Figure 5 - Zone Input (No Resistors)
Figure 4 - Zone Input (No Resistors)
Zone 1 (1+2)
Zone 1
N.C. Zone Contact
0V
Zone 2
N.C. Zone Contact
Zone 2 (3+4)
PURPLE
ORANGE
BLACK
Zone 3
Zone 3
N.C. Zone Contact
0V
Zone 4
N.C. Zone Contact
Zone 4
YELLOW
GREEN
GREY
7