Installation manual

4.3 Zone Input Wiring
The Protégé® EliteSuite® Eclipse LED Keypad is capable of connecng to 8 zone inputs, each zone
input can then be programmed to perform the required funcon in the system.
The following diagrams show each of the zone wiring conguraon sengs that are possible.
The programmed zone conguraon for the Protégé® EliteSuite® Eclipse LED Keypad is made in the
opon sengs. RefertotheGeneralOponssecononpage23forprogrammingofthezone
conguraon.
!
When using a tamper input on a device the tamper contacts must be normally
closed and wired in series.
!
All resistors required to wire the zone conguraons are provided with the
Protégé® EliteSuite® Eclipse LED Keypad in the accessory bag.
Figure 5 - Zone Input (No Resistors)
Figure 4 - Zone Input (No Resistors)
Zone 1 (1+2)
Zone 1
N.C. Zone Contact
0V
Zone 2
N.C. Zone Contact
Zone 2 (3+4)
PURPLE
ORANGE
BLACK
Zone 3
Zone 3
N.C. Zone Contact
0V
Zone 4
N.C. Zone Contact
Zone 4
YELLOW
GREEN
GREY
7