Product Manual
35
Appendix A
"Record your message
after the tone, when you
are done press the pound
key."
"You are now in the main menu.
For current status press 1.
For remote switch status, press 2.
To enter programming menu, press 3."
"The current temperature is xx
degrees, the power is on/off, the
battery is at x.xx volts and the
auxiliary input is currently not in/in
alarm mode.
"To review or program first telephone number, press 1.
To review or program second telephone number, press 2.
To review or program third telephone number, press, 3.
To review or program pager display information, press 4
To return to the main menu, press 9."
"(First / Second / Third) telephone number is currently
xxxx / empty / pager, to change, press zero or press 9 to
return to the main telephone number menu."
Using the keys on
your touch-tone
phone, enter the
phone number
followed by the
pound key.
"To review or program the low
temperature alarm setpoint
press 1. To review or program
the high temperature alarm
setpoint, press 2. To return to
the main menu, press 9."
"The (high / low) temperature alarm setpoint is now xxx
degrees. To change, press zero or press 9 to return to
the temperature setpoint menu."
"Enter the (high / low)
temperature alarm setpoint
followed by the pound key.
"The security code is
currently xxxx. To change,
press zero, or press 9 to
return to the main menu."
"Enter the security
code followed by the
pound key."
"The FreezeAlarm is
currently set to answer on
xx rings. To change, press
0, or press 9 to return to
the main menu."
"Enter the
number of rings
followed by the
pound key."
To review or record Greeting Message,
press 1. To review or record Main
Alarm Message, press 2. To review or
record Auxiliary Alarm Message, press
3. To return to the main menu, press 9
"The position of the remote switch is
currently (T1 / T2). To change, the
position to (T2 / T1), press zero, or to
return to the main menu press 9."
"To review or program phone numbers, press 1.
To review or program the temperature alarm set-point, press 2.
To review or program the security code, press 3.
To review or program the number of rings before the unit
answers, press 4.
To review or program the number of minutes the power should
be out before calling with a power alarm, press 5.
To review or record messages, press 6.
To review or modify the auxiliary alarm setting, press 7
To return to the main menu, press 9."
1
3
1
9
1, 2 or 3
2 - Temperature Alarm Setpoint
9
1 or 2
0
9
3 - Security Code
9
0
#
#
4 - Ring Count Selection
9
9
2
9
0
9
6 - Messages
0
#
The FreezeAlarm is currently set to
alarm if the power is out for xx
minutes. To change, press 0, or
press 9 to return to the main menu.
Enter the number of minutes the power
should be out before calling with a power
alarm, followed by the pound key.
9
5 - Power Alarm Timer
0
#
1, 2, 3
9
0
#
Main Menu - FA-D2
The auxiliary alarm input is currently set as a
normally open/closed contact. To change,
press 0 or press 9 to return to the main menu.
Pressing zero will play back
the same menu, but with
the selection changed.
0
7 - Aux Alarm Setting
9
To review or program pager display
information, press 2, or press 9 to
return to phone number menu.
4
Pager display information is
currently XXXX/empty. To
change, press 0, to return to
main pager display menu,
press 9
2
9
Using the keypad on your touch
tone phone, enter the number
to be displayed on the pager
during an alarm call out
followed by the pound key.
When zero is
pressed, return
them back to this
menu and play
changed status of
remote switch.
The (Greeting/Main
Alarm/Auxiliary Alarm) Message
is currently: play message. To
record a new message, press 0
or to return to the message
menu, press 9.
0
9
9
0
If this is a pager number,
press 1, if not, press 2.
#
1 or 2
PAGER INFO:
If a number is
identified as a
pager number,
when playing
back the
number, play
the word
"PAGER" after
the number.
36
"Hello, this is your Automated Monitoring Control
System. The current temperature is xx degrees, the
power is on/off and the battery is at x.xx volts."
"There are no alarm conditions
occurring at this time. To access the
main menu, enter your four digit
security code followed by the pound
key."
There is an alarm condition at your remote
monitored location, the following alarms
currently exist or have occurred recently. There
is a temperature alarm. The power has been
out for XXXX minutes and is currently ON/OFF.
There is a battery alarm. The auxiliary input is
in alarm mode (Or play the user's recorded
auxiliary alarm message here instead). Please
check conditions at your monitored location
immediately."
"To access the main menu,
enter your four digit security
code followed by the pound
key."
No Alarms
Present
NOTE: If there is a personal greeting message recorded, the
Freeze Alarm would answer as follows: [Personal message].
The current temperature is xx degrees, ...."
In addition, for call-in, we're not going to give the aux. alarm
status. It is stated later if it is in alarm mode. No need to state
it earlier.
"To cancel the alarm call-out,
enter your four digit security
code followed by the pound
key."
"Incorrect security code.
Enter your four digit security
code followed by the pound
key."
"Incorrect security code.
Enter your four digit security
code followed by the pound
key."
"Incorrect security
code, good bye."
"The alarm call-out is
now canceled."
"You are now in the main
menu."
One or more
alarms present
Incorrect
Security code.
Incorrect
Security code.
Incorrect
Security code.
Alarm call-out has
been canceled.
Alarm call-out
is active.
Correct
security
code.
Correct
security
code.
Incorrect
security
code.
Incorrect
security code.
Correct
security code.
Correct
security
code.
Correct
security
code
Call in menu for FA-D2
NOTE: Only play
the alarms which are
currently in fault.
For the auxiliary alarm,
we will play the custom
recorded message
instead of "The auxiliary