SORADIO EN SORADIO Installation instructions - Pages 2-15 529 VISTA BLVD 89434 SPARKS, NV - USA Toll Free: 1-800-498-9662 / Phone: (775) 856-7333 / Fax: (775) 856-7658 Website: www.protechusa.com E-mail: sales@protechusa.
PROTECH SORADIO
PROTECH SORADIO CONTENTS 1 2 WIRING ............................................................................................................. 2 SMARTPHONE APPLICATION ........................................................................ 3 2.1 2.2 2.3 2.4 2.5 2.6 3 Settings .............................................................................................................................. 4 Input status ....................................................................................
PROTECH 1 SORADIO WIRING N° Terminals 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 L1 L2 L3 * Description Input 1 Common Input 2 Common Input 3 Common Input 4 Common Input 5 Common Input 6 Common Input 7 Common Input 8 Common X X X X 0V Power supply +12V DC Power supply Note: All common inputs are connected together. Example of input wiring: C E1 The inputs are seen out of alarm when they are closed. They are seen in alarm when they are open (Positive security).
PROTECH 2 SORADIO SMARTPHONE APPLICATION Note: The smartphone application is compatible from Android 4.1 or higher. 1. Download the smartphone application “Sorhea Connect”. Sorhea Connect 2. Launch application “Sorhea Connect”. Authorize activation of Bluetooth if requested to do so by the application. 3. Press the tamper switch very briefly (1s) to activate the BLE connection of the SORADIO. Note: the connection remains active as long as the SORADIO is connected to the smartphone application.
PROTECH SORADIO 5. Click on the product found. SORADIO found Radio ID of the SORADIO found identical to the sticker on the card. 2.1 Settings Setting the time on the module Enter the module name: Click on the name to change and Save 2.2 Input status Real-time input status Legend: No alarm Alarm Inactive Note: It is possible to customize the name of an input. Click on the name to change and Save.
PROTECH SORADIO 2.3 Input settings Each input can be: • Enable / disable input. • Eject input. To apply the changes, click Save. Select Input disable input Eject input Not used Enable input Input disabled Input enabled Eject input Input not ejected Input ejected Note: It is only possible to eject an input if it is enable. Input disable = Relay associated forced in alarm Input ejected = Relay associated forced out alarm. 2.
PROTECH SORADIO 2.4.
PROTECH SORADIO 2.5 Event log 1. Click on Menu Menu 2. Click on Event log Event log 3.
PROTECH SORADIO 2.6 Network settings 1. Click on Menu Menu 2. Click Network settings Network Settings Indication that radio is active The black point "●" indicates that the SORADIO has no assigned channel.
PROTECH 3 SORADIO RADIO CONFIGURATION 3.1 Configuration using the CONNECT RADIO COORDINATOR 1. Enable radio, see §3.2.Activate the radio on the SORADIO. Note: By default, the radio is disabled. 2. Refer to manual CONNECT RADIO COORDINATOR NT400 to start radio search. 3. SORADIO settings and status from UNIVERSAL MAXIBUS A B C D A. Product Name: Possibility to customize the name of the connected product. Change the name and click SAVE. B. Reading network address RS485 (unused in SORADIO). C.
PROTECH SORADIO D. Note: It is only possible to eject an input if it is enable. Input disable = Relay associated forced in alarm Input ejected = Relay associated forced out alarm. E. Input State (Note: status not available in radio mode) No alarm Alarm Disable 4.
PROTECH SORADIO 3.2 Activate the radio on the SORADIO Note: radio activation allows resetting the radio configuration on the SORADIO and switching to radio search (wait for pairing with the CONNECT RADIO COORDINATOR) 1. Disconnect the power supply on the SORADIO 2. Press the button and switch on the SORADIO L1 L2 L3 3. Hold the button until the orange LED L2 lights. (≈ 5s, The green led L1 lights up during the procedure).
PROTECH 4 SORADIO MAINTENANCE Failure Probable causes Solutions Permanent alarm - Input disabled Non-wired entry - Activate input. Check wiring. Never alarm - Input ejected - Remove ejection from input The smartphone application does not detect the - The BLE connection of the 8 INPUTS REMOTE MODULE is not activated. SORADIO 5 Press the tamper for at least 1 second.
PROTECH 6 SORADIO PRODUCT REFERENCES • SORADIO ref: 30790001 Option: • • • • Pole mount bracket set Ø76 Pole mount bracket set Ø101 Bracket set for mounting on 100x50 pole or frame 3100 SF Bracket set for mounting on frame 3100 DF ref: 30793001 ref: 30793002 ref: 30793003 ref: 30793004 Changes or modifications not expressly approved by PROTECH / SORHEA could void the user’s authority to operate the equipment. FCC Part 15 compliance statement This device complies with part 15 of the FCC Rules.
PROTECH SORADIO ISDE (Canada) appareils radio exempts de licence L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : 1. L’appareil ne doit pas produire de brouillage ; 2.