Specifications
4
3
FEATURES & BENEFITS
Typical Applications
n Conveyors
n Cranes and Hoists
n Extruders
n Indexing Tables
n Packaging Machinery
n Feeders
Minarik’s RG500A Series consists of full-wave, four-quadrant regenerative
SCR drives in a NEMA 4X enclosure to provide smooth motoring and braking
torque for brush-type DC motors. Mounted operators include power on/off
switch, speed potentiometer and reverse/brake/forward switch. These drives
are ideal in applications requiring protection from washdown, splashing liq-
uids, corrosive material, windblown dust, incidental contact with enclosed
equipment, or any external solid objects.
Slide switches allow the RG500A and RG510A drives to accept a 115 or 230
VAC input to run 90 or 180 VDC motors. A field supply is also provided for
shunt-wound motors. The switch selectable tachometer feedback mode virtu-
ally guarantees constant set speed under varying load.
The RG is compatible with the PCM4 signal isolator, the DLC digital controller
and the 200-0386A limit switch logic board.
Applications with overhauling loads, rapid deceleration, basic positioning,
and high duty cycle reversing and braking benefit from these versatile regen-
erative drives.
n NEMA 4X enclosure: Rugged metal enclosure protects against dirt, water and corrosive agents.
n 4Q reversing: Regenerative/4 quadrant drives have the ability to perform quick contactorless reversing on-the-fly!
n Speed range and regulation: 1% regulation over 50:1 speed range. 0.1% regulation over 60:1 speed range
with the addition of a tachometer for feedback. Armature or tachometer mode is switch selectable.
n User adjustable calibration pots: IR compensation, forward torque, reverse torque, tachometer, min speed,
max speed, forward acceleration, reverse acceleration and deadband.
n Diagnostic LEDs: Power On light on front of enclosure.
n Stopping modes: User can regeneratively brake (run/brake), coast the motor (power on/off switch), or
decelerate to a stop (N.O.). User can also decelerate to min speed (N.C.).
n Screw terminal block: Easy and secure wire terminations.
n On board fusing: No need to add external fusing for protection of your drive.
RG500A Dimensions
RG500A Series Specifications
RG510A
RG500A
115/230
115/230
0-90 or
0-180
0-90 or
0-180
50/100/200
(1 Amp)
50/100/200
(1 Amp)
1/20 - 1/8 @ 90 VDC or
1/10 - 1/4 @ 180 VDC
1/4 - 1 @ 90 VDC or
1/2 - 2 @180 VDC
3.0
1.37
10.0
Max Output
Current (ADC)
Field Supply
(VDC)
Output
Voltage (VDC)
Input Voltage
(VAC)
Models
Form
Factor
Hp Rating
1.37
Three 0.88 [22] knockouts
All dimensions in inches [millimeters]
10.20
[259]
9.80 [249]
6.90 [175]
6.30 [160]
1.40 [36]
5.50[140]
4.78 [121]
2.30 [56]
1.45
[37]
0.12
[3]
1.50 [38]
1.50 [38]
1/20 to 2 Hp
SCR DC Regen NEMA 4X
RG500A Series
RG500A
For matching DC motors , see pages 37 to 48.
Drives operate from 50 - 60 Hz.
Call us toll free 1•800•MINARIK or download manuals at www.minarikdrives.com
C
REGENERATIVE DRIVES