Technical data

53
Flexible Tracer Heaters
450 °C
Type HBS
Type HB
Heating Tapes
Only suitable for a dry environment, safety earthed and very fl exible
design. Multiple glass fi lament insulation with additional protective
conductor over the heating conductor. One-sided connection. For
multifarious use in laboratories, technical colleges and industry.
This version HB has no protective conductor. It is thus even thinner
and smoother than the HBS series heating tapes.
HBS
Operating temperature:
7.0 m max. 450°C
10.0 m max. 350 °C
Rated voltage:
230 V AC/ DC
Rated power:
app. 250 W/m
Min. bending radius:
10 mm
Outer dimensions:
5.5 x 30 mm (thickness x width)
Outer jacket:
glass fi bre
Connecting cable:
0.5 m with connection box
Protection grade:
IP 20 (EN 60529)
safety conductor braiding:
nickel
Protection class:
I
HB
Operating temperature:
7.0 m max. 450°C
10.0 m max. 350 °C
Rated voltage:
230 V AC/ DC
Rated power:
app. 250 W/m
Min. bending radius:
6 mm
Outer dimensions:
3.5 x 30 mm (thickness x width)
Outer jacket:
glass fi bre
Connecting cable:
0.5 m with connection box
Protection grade:
IP 20 (EN 60529)
safety conductor braiding:
no
Protection class:
0
Metres Watt Order Nr.
0,5 100 HBS/005 HB/005
1,0 250 HBS/010 HB/010
1,5 350 HBS/015 HB/015
2,0 500 HBS/020 HB/020
2,5 600 HBS/025 HB/025
3,0 750 HBS/030 HB/030
4,0 900 HBS/040 HB/040
5,0 1250 HBS/050 HB/050
7,0 1550 HBS/070 HB/070
10,0 2000 HBS/100 HB/100
15,0 3000 HBS/150
Temperature control using our control equipment, as listed in
chapter 6 Temperature Controllers.
450 °C
Heating
conductor
Heating
conductor
Glass yarn
insulation
Glass yarn
insulation
Glass fi bre
Glass fi bre
Saftey conductor
braiding