Technical data

43
Flexible Tracer Heaters
450 °C
Type HS
Heating cord with tight winding radii
Glass fi lament insulated heating cord. Very fl exible, especially suit-
able for tight winding radii and concentrated power.
The connecting cables are glass fi bre insulated.
Operating temperature:
max. 450°C
Rated voltage:
230 V AC/DC
Min. bending radius:
4 mm
Connecting cable:
1.5 m on both ends
Diameter:
Ø 3 - 4 mm
Degree of protection:
IP 20 (EN 60529)
Safety conductor braiding:
no / not moisture proof
Protection class:
0
Type HSS 450 °C
with additional conductor wire sheathing.
Construction is equivalent to Type HS
Operating temperature:
max. 450°C
Rated voltage:
230 V AC/DC
Min. bending radius:
6 mm
Connecting cable:
1.5 m on both ends
Diameter:
Ø 3.5 – 4.5 mm
Degree of protection:
IP 20 (EN 60529)
Safety conductor braiding:
nickel, not moisture-proof
Protection class:
I
Metres Watt Order Nr.
0,6 75 HS/006 HSS/006
1,0 100 HS/010 HSS/010
2,0 250 HS/020 HSS/020
3,0 350 HS/030 HSS/030
4,0 500 HS/040 HSS/040
5,0 600 HS/050 HSS/050
6,0 800 HS/060 HSS/060
8,0 1000 HS/080
10,0 1250 HS/100 HSS/100
15,0 1500 HS/150
In addition to the listed lengths, larger lengths and capacities as
well as intermediate lengths can also be supplied. Where required,
please state the length and power of the heating cord.
Temperature control using our control equipment, as listed in
chapter 6 Temperature Controllers.
Heating Cords
Heating
conductor
Glass yarn insulation Saftey conductor
braiding
(nickel)
Flexible Tr
a
Heating
conductor
Glass yarn insulation