Technical data
5
General Pointer and Facts
General
Nominal size: The nominal size (inside diameter) is abbreviated as NW or (English) DN, and is
determined by the fl ow quantity and/or the viscosity of the medium. Standard in PTFE (T1...T4) 4....
50 mm, stainless steel (T5) from DN6. Larger dimensions are available on request (see also page
31 transfer - unload hoses).
Hydraulic pressure hoses: The hydraulic pressure hose type is mainly determined by the same
parameters as the nominal size. Added to this is the operational pressure. Other selection criteria
like heat transfers, bending radius or strongly pulsating loads are also important parameters. The
table about the bending radius and operational pressure can be found on page 8. We also heat
special hoses made of Viton, silicone, NBR... that can be supplied on request.
Attention! ➞ The data is defi ned for temperatures from 20...50°C. Increased temperatures
decrease operational pressure loads; please adhere to temperature correction factors.
Connection fi ttings: The selection of the fi ttings is dependent on the nominal size and the opera-
tional pressure load resistance of the hose (light, medium and strong fi ttings range). The standard
range is shown on page 6-7. The heating hose may be fi tted with different fi tting on either side.
Additionally open ends without fi ttings and many types of special type fi ttings (clamp, fl ange, milk
pipe...) are available on request.
Temperature sensor(s): As standard our heating hoses are fi tted with Fe-CuNi (J) thermo ele-
ments. As standard we also apply NiCr-Ni(K) thermo elements and PTC sensors PT100 in 2-wire
connections (3 and 4-wire connections are possible). Other thermo elements types and PTC/NTC
sensors are available on request. Depending on application a variety of sensors can be installed.
The HTI or HTP integral action controller will control the temperature directly at the heating wire
with PTC behaviour.
Control pipes: The assembly of the heating hose can include a variety of electrical connection pipes,
fl exible piping for air, test gas or fl uid media, even in combination. The entry and exit point and
the corresponding connection elements (connections, couplings...) have to be determined. Parallel
pickups enable the connection of additional consumers at the same basic guidelines. Conductor
cross-sections and pipe diameter depend on the connected consumers.
Connection / plug connection: The access line can be taken out from the end cap as described
on page 11. Industrial hoses normally have 1.5 m, analyser connections 3.0 m long connection
pipes. Special models with relegated outputs, different dimensions, separate pies for heating, sen-
sors and control pipes .... can be realised.
The heating hose is fi tted with a connector that matches our control appliances. Basis is the tempera-
ture controller HT43 with a circular connector 6+PE (page 84). Please note that for a non-monitored
operation an additional fuse has to be installed in the heating system (limiter, temperature control
fuse…).
We can also supply devices without connectors for the connection of clamps or the assembly of
customer-specifi ed connectors. We use the connectors of many well-known manufacturers. We can
assemble such parts for you, if you state the pin connections with your order specifi cations.
Heating-up time/safety: Under normal conditions the heating-up time will be between 15 to
30 minutes (enclosed space, approx. 20°C). Before commissioning it has to be ensured that the
medium in the hose and the connection points has reached processing temperature. Bending loads
and plug-ups in the fi tting before reaching the processing temperature may damage the hose.
Before commissioning please read our operational and assembly instructions.