Technical data

4
General Pointer and Facts
Technical Data
Rated power watt/meter at 230 V ~
for standard-heating hoses
Type DN 4 6 8 10 12 16 20 25 32 40 50
H 100 100 °C 80 100 120 140 160 200 260 330 380 440 550
H 700
H 200
H 800
200 °C
250 °C
100 120 140 160 200 260 330 380 440 550 660
H 900 450 °C 220 250 280 310 400 460 610 660 880
H 400 80 °C 70 70 70 90 90 120 120
outer-Ø
with standard
braiding
40 40 40 45 45 50 50 55 60 70 85
Special power and voltage on request.
Rated power watt/meter
for analytical heating hoses series H 300
Typ DN 4 6 81012
H 300 100 °C 100 120 140 160 200
H 300 A+C 200 °C 120 140 160 200 260
H 300 350 °C 200 220 250 280 310
H 300 A 350 °C 220 250 280 310 400
Tolerances
Rated power:
+ 5% / -10%
Diameter:
± 10%
Data length in meter:
± 2%
Testing voltage of heating hoses
(230 V allowable stress)
2000 Volt High voltag testing
Heating conductor – Safety conductor
Information about Hillesheim heating hoses
Electrical engineering: Power supply and wire whip have been prepared for the specifi ed volt-
age connection (rated voltage) and the wire whip type. The connection is laid out in accordance
with CE standards (DIN-VDE...). Design in accordance with other guidelines can be arranged (UL,
CSA, SEV...).
The heating is designed in such a way that an optimal heat distribution is achieved for the entire
length.
Heating hoses are fi tted with temperature sensors and have to be monitored by suitable control
devices. For non-monitored operation we can install additional sensors (bimetal controls, thermal
fuses...), or additional temperature sensors to be connected to the controls-limiters combination
(Sicherheit in Elektrowärmeanlagen (Safety in electrical thermal equipment) DIN EN 60619-2 [VDE
0721 Part 411]).
The design shown on page 2 shows a schematic illustration of the heating hose. The hose type and
application may be reason for differences. Additionally the design may differ due to new and further
developments.
Please note! Standard heating hoses may not be used in explosion hazardous areas. Our hose
series H600 is designed for use in ex-zones 1 and 2 and/or 21 and 22 (page 27), which we can
modify correspondingly for your application.