Instructions / Assembly
Wire Harness
23 www.pro-team.com 866.888.2168
TO PERFORM A FUNCTION TEST:
1. Reinstall handle assembly and cord.
2. Install Intercept Micro Filter.
3. Plug in vacuum and turn vacuum on in the number two (II) position.
4. Powerhead motor should be running. Release vacuum from upright locked position.
5. The brush roll motor should stop and the red warning light should light up. Release the switch and the
powerhead should go back to normal operation.
6. Turn the vacuum on in position number one (I). The vacuum motor should be on. Pull out the wand and cover
the end of the wand with your hand. This will simulate blockage and the bag full light should come on. Take
your hand off the end of the wand and the light should turn off. If your vacuum passes these tests, your
vacuum is ready to use.
Attach new blue and black wires.
28.
Replace base cover and screws.
29.
To Reassemble.
Reverse Steps 29 through 1 to finish reassembly.
WIRE HARNESS REPLACEMENT (CONTINUED FROM PAGE 22)
LOCKOUT
SWITCH ON XP
MODELS ONLY