TROUBLE SHOOTING GUIDE
PROBLEM PROBABLE CAUSE POSSIBLE SOLUTION
Unit is activated but nothing
happens
No Power
Timer clears after priming
Remote timers do not
work
Check to see if the power
source has been properly
connected
Restart the timer and try
again
Check connections to both
– replace if defective
Bed appears too be to hot
Fans are obstructed
Ensure all fans are clear of
obstructions and dust.
Room Temperature abnormally
warm.
Bed is too close to the wall Pull the bed away from
the wall at least 6 – 12
inches.
Individual lamps do not light
Lamp not properly in
socket
Lamp is defective
Starter is defective
Ballast defective
Loose wire
Turn lamp in socket until
lamp illuminates
Replace lamp
Replace starter
Replace ballast
Reconnect wire
Facial tanner does not light
Face tanner switch is
turned to “Off” position
Lamp is defective
Switching from “On” to
“Off” and back again too
quickly
Turn face tanner switch to
“On” position
Replace lamp
Wait a few minutes after
switching facials back
“On” again (approximately
3 minute cool down time)