User manual
Configuration Commands RLXIC-SV ♦ Intelligent Cellular
User Manual RadioLinx Intelligent Cellular Serial Modem for the Verizon Wireless CDMA Network
ProSoft Technology, Inc. Page 111 of 146
May 29, 2009
Tip: Flow control (AT\Q) will override this indication, so if you want to use CTS to indicate network
coverage, flow control has to be off (AT\Q0).
*MODEMHISPEED
Set the internal serial link speed to the internal (radio) module.
n=0 : 115200 and 38400 for iDEN (default)
n=1 : 230400 and 115200 for iDEN
n=0 : 115200 (default)
n=0 : 38400 (default)
n=0 : 115200 (default)
n=0 : 38400 (default)
n=1 : 230400
n=1 : 115200
This command is only available with CDMA, iDEN, EDGE, or GPRS modems.
May not be available for all modem models.
*NUMTOIP=n
Convert 12 digit number to IP.
n=0 : Use as name.
n=1 : Use as IP address.
*PPPNOCARRIER=n
Provides a "No Carrier" message to a device connected to the serial port using
PPP or CHAP when the cellular connection becomes unavailable.
n=0 : Disabled (Default).
n=1 : Enabled.
11.3.3 TCP
This group includes commands specific to TCP serial communications.